- | | 1.1.0 | 2023-07-24 | + | | 1.1.0 | 2023-07-24 |
- | | 1.0.0 | 2022-12-04 | + | | 1.0.0 | 2022-12-04 |
===== Features ===== | ===== Features ===== | ||
Line 67: | Line 67: | ||
===== Configuration ===== | ===== Configuration ===== | ||
- | No specific configuration is required in TeemIp' | + | No specific configuration is required in TeemIp' |
+ | ==== Configuration file ==== | ||
+ | Under the **Modules specific settings** section, default parameters used by the **Find wiring** action on Cross Connects may be overwritten by the following configuration lines. | ||
+ | < | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ), | ||
+ | ), | ||
+ | </ | ||
+ | |||
+ | ==== Global IP Settings ==== | ||
+ | Under the **Other Settings** fieldset, the **Allow cabling toward another organizations** parameters enables patch panels from a given organization to be connected to patch panels of other organizations. | ||
+ | |||
+ | {{ cabling_ipsettings.png }} | ||
===== Patch Panel ===== | ===== Patch Panel ===== | ||
{{icons8-toolbar.svg | {{icons8-toolbar.svg | ||
Line 82: | Line 97: | ||
| Location | Foreign key to a(n) Location | Yes | | | Location | Foreign key to a(n) Location | Yes | | ||
| Capacity | Number of network sockets that the panel can host | No | | | Capacity | Number of network sockets that the panel can host | No | | ||
- | | Connector | Foreign key to a(n) Interface Connector \\ Brought by the [[extensions: | + | | Connector | Foreign key to a(n) Interface Connector \\ Brought by the [[extensions: |
+ | | External reference | Alphanumeric string | ||
| Description | Multiline character string | No | | | Description | Multiline character string | No | | ||
| **Rack Information** ||| | | **Rack Information** ||| | ||
Line 118: | Line 134: | ||
=== Creating back end network cables === | === Creating back end network cables === | ||
- | If some network sockets are already attached to the patch panel, TeemIP will offer to automatically connect the back end interface of these network sockets to remote sockets located in another patch panel of another Rack. Purpose of this action | + | If some network sockets are already attached to the patch panel, TeemIP will offer to automatically connect the back end interface of these network sockets to remote sockets located in another patch panel of another Rack. This action |
When action is launched, TeemIP offers first to select the remote patch panel... | When action is launched, TeemIP offers first to select the remote patch panel... | ||
Line 126: | Line 142: | ||
.. before creting the links in accordance with the number of available sockets in the remote rack. | .. before creting the links in accordance with the number of available sockets in the remote rack. | ||
+ | <note tip> | ||
+ | By default, the remote patch panel must belong to the same organization as the source one. This behaviour may be changed through the parameter **Allow cabling toward another organizations** of the Global IP setting of the source organization, | ||
+ | </ | ||
===== Network Socket ===== | ===== Network Socket ===== | ||
{{icons8-wired-network.png | {{icons8-wired-network.png | ||
Line 139: | Line 158: | ||
| Patch panel | Foreign key to a(n) Patch Panel | No | | | Patch panel | Foreign key to a(n) Patch Panel | No | | ||
| Organization | Organization that the patch panel belongs to | N/A | | | Organization | Organization that the patch panel belongs to | N/A | | ||
+ | | External reference | Alphanumeric string | No | | ||
| Comment | Multiline character string | No | | | Comment | Multiline character string | No | | ||
| **Front End Information** ||| | | **Front End Information** ||| | ||
Line 187: | Line 207: | ||
===== Cross Connect ===== | ===== Cross Connect ===== | ||
{{icons8-data-transfer.svg | {{icons8-data-transfer.svg | ||
- | FIXME | ||
A cross connect represents the cabling necessary to establish a direct link between two separate organizations in a data center, thus allowing the establishment of a private network link and eliminating the need to connect them using the internet. | A cross connect represents the cabling necessary to establish a direct link between two separate organizations in a data center, thus allowing the establishment of a private network link and eliminating the need to connect them using the internet. | ||
Line 230: | Line 249: | ||
{{ classdisplay_crossconnect.png }} | {{ classdisplay_crossconnect.png }} | ||
+ | === Finding Wiring Paths === | ||
+ | A cross connect documents a link between one or two network socket hosted in a patch panel sitting in a rack of a given organization and one or two peer network socket hosted in a peer patch panel sitting in a peer rak of a peer organization. The **Find wiring paths** action will display all the available cabling paths that may be establish to connect 2 network sockets that answer to the previous conditions. | ||
+ | {{ classdisplay_crossconnect_find_path.png }} | ||
+ | Network admin may select one of the offered path and manually create it within TeemIP. | ||
+ | <note tip> | ||
+ | The **Find wiring paths** action doesn' | ||
+ | * The number of racks that the paths may cross is limited to **5**, | ||
+ | * The maximum of offers or proposals made by the tool is set to **32**. | ||
+ | |||
+ | These value can be overwritten through the configuration file, as described [[extensions: | ||
+ | </ | ||
===== Physical Interface ===== | ===== Physical Interface ===== | ||
{{icons8-globe-wire.png | {{icons8-globe-wire.png | ||
Line 283: | Line 313: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the front end network cable | |
<note warning> | <note warning> | ||
Line 317: | Line 347: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the back end network cable | |
<note warning> | <note warning> | ||
Line 352: | Line 382: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the device |
<note warning> | <note warning> | ||
Line 387: | Line 417: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the direct |
<note warning> | <note warning> | ||
Line 423: | Line 453: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Patch Panels | All the patch panels that the cable is connected to | | + | | Documents | All documents linked to the breakout cable | |
+ | | Patch Panels | ||
- | The relation holds a " | + | (*) The relation holds a " |
<note tip> | <note tip> |