This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
extensions:teemip-cable-mgmt [2024/02/23 17:31] – [Front End Network Cable] cnaud | extensions:teemip-cable-mgmt [2024/05/14 13:04] (current) – [Patch Panel] cnaud | ||
---|---|---|---|
Line 32: | Line 32: | ||
===== Revision History ===== | ===== Revision History ===== | ||
^ Version | ^ Version | ||
- | | 1.3.0 | 2024-0x-xx | + | | 1.3.0 | 2024-0x-xx |
- | | **1.2.0** | + | | **1.2.0** |
- | | 1.1.0 | 2023-07-24 | + | | 1.1.0 | 2023-07-24 |
- | | 1.0.0 | 2022-12-04 | + | | 1.0.0 | 2022-12-04 |
===== Features ===== | ===== Features ===== | ||
Line 67: | Line 67: | ||
===== Configuration ===== | ===== Configuration ===== | ||
- | No specific configuration is required in TeemIp' | + | No specific configuration is required in TeemIp' |
+ | ==== Configuration file ==== | ||
+ | Under the **Modules specific settings** section, default parameters used by the **Find wiring** action on Cross Connects may be overwritten by the following configuration lines. | ||
+ | < | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ), | ||
+ | ), | ||
+ | </ | ||
+ | |||
+ | ==== Global IP Settings ==== | ||
+ | Under the **Other Settings** fieldset, the **Allow cabling toward another organizations** parameters enables patch panels from a given organization to be connected to patch panels of other organizations. | ||
+ | |||
+ | {{ cabling_ipsettings.png }} | ||
===== Patch Panel ===== | ===== Patch Panel ===== | ||
{{icons8-toolbar.svg | {{icons8-toolbar.svg | ||
Line 113: | Line 128: | ||
With the extension [[https:// | With the extension [[https:// | ||
- | FIXME | ||
{{ classdisplay_patchpanel-dcviewext.png }} | {{ classdisplay_patchpanel-dcviewext.png }} | ||
Line 120: | Line 134: | ||
=== Creating back end network cables === | === Creating back end network cables === | ||
- | If some network sockets are already attached to the patch panel, TeemIP will offer to automatically connect the back end interface of these network sockets to remote sockets located in another patch panel of another Rack. Purpose of this action | + | If some network sockets are already attached to the patch panel, TeemIP will offer to automatically connect the back end interface of these network sockets to remote sockets located in another patch panel of another Rack. This action |
When action is launched, TeemIP offers first to select the remote patch panel... | When action is launched, TeemIP offers first to select the remote patch panel... | ||
Line 128: | Line 142: | ||
.. before creting the links in accordance with the number of available sockets in the remote rack. | .. before creting the links in accordance with the number of available sockets in the remote rack. | ||
+ | <note tip> | ||
+ | By default, the remote patch panel must belong to the same organization as the source one. This behaviour may be changed through the parameter **Allow cabling toward another organizations** of the Global IP setting of the source organization, | ||
+ | </ | ||
===== Network Socket ===== | ===== Network Socket ===== | ||
{{icons8-wired-network.png | {{icons8-wired-network.png | ||
Line 233: | Line 250: | ||
=== Finding Wiring Paths === | === Finding Wiring Paths === | ||
- | A cross connect documents a link between one or two network socket hosted in a patch panel sitting in a rack of a given organization and one or two peer network socket hosted in a peer patch panel sitting in a peer rak of a peer organization. | + | A cross connect documents a link between one or two network socket hosted in a patch panel sitting in a rack of a given organization and one or two peer network socket hosted in a peer patch panel sitting in a peer rak of a peer organization. |
{{ classdisplay_crossconnect_find_path.png }} | {{ classdisplay_crossconnect_find_path.png }} | ||
Network admin may select one of the offered path and manually create it within TeemIP. | Network admin may select one of the offered path and manually create it within TeemIP. | ||
+ | |||
+ | <note tip> | ||
+ | The **Find wiring paths** action doesn' | ||
+ | * The number of racks that the paths may cross is limited to **5**, | ||
+ | * The maximum of offers or proposals made by the tool is set to **32**. | ||
+ | |||
+ | These value can be overwritten through the configuration file, as described [[extensions: | ||
+ | </ | ||
===== Physical Interface ===== | ===== Physical Interface ===== | ||
{{icons8-globe-wire.png | {{icons8-globe-wire.png | ||
Line 429: | Line 454: | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
| Documents | All documents linked to the breakout cable | | | Documents | All documents linked to the breakout cable | | ||
- | | Patch Panels | All the patch panels that the cable is connected to | | + | | Patch Panels |
- | The relation holds a " | + | (*) The relation holds a " |
<note tip> | <note tip> |